Physical Testing of LMM-600 Laser Marks

Laser marks were made on type 304 stainless steel tags using LMM-6000 and a CO2 Laser.

Marks were made at settings of 100% power, 12% speed, 500 DPI on a 35 watt Universal Laser.

Tags were totally immersed in the test solutions.

Test results provided by Ferro Corporation.

 

Exposure Time

 

 

Organic Solvents

 

1 Hour

12 Hours

24 Hours

1 Week

Gasoline

 

No effect

No effect

No effect

No effect

Limonene

 

No effect

No effect

No effect

No effect

Methyl Ethyl Ketone

 

No effect

No effect

No effect

No effect

N-Butanol

 

No effect

No effect

No effect

No effect

Mineral Spirits

 

No effect

No effect

No effect

No effect

Xylene

 

No effect

No effect

No effect

No effect

Acetone

 

No effect

No effect

No effect

No effect

Propylene Carbonate

 

No effect

No effect

No effect

No effect

Ethanol

 

No effect

No effect

No effect

No effect

DMSO

 

No effect

No effect

No effect

No effect

Motor Oil

 

No effect

No effect

No effect

No effect

 

 

 

Acid/Bases

 

Hydrochloric Acid 35%

 

No effect

No effect

Test stopped - see notes

Nitric Acid 68%

 

No effect

No effect

No effect

No effect

Sulfuric Acid (conc.)

 

No effect

No effect

No effect

No effect

Acetic Acid 99.5%

 

No effect

No effect

No effect

No effect

Hydrogen Peroxide 30%

 

No effect

No effect

No effect

No effect

Sodium Hydroxide 25%

 

No effect

No effect

No effect

No effect

Ammonium Hydroxide 20%

 

No effect

No effect

No effect

No effect

 

 

Other

 

Boiling H2O

 

Marks soaked in boiling water for 1 hr. - no effect

LN2 (Cold)

 

Marks dipped in liquid nitrogen - no effect

Flame (Hot)

 

Marks heated in a propane flame until cherry red - metal discolors, no effect on mark.

Hot/Cold Cycling

 

Marks heated red hot and immediately plunged in liquid nitrogen - metal discolors, no effect on mark

 

Notes:

 

Hydrochloric acid testing:

 

 

 

 

 

- Acid dissolves the steel tag and was not run over 12 hrs. long

- After 1 hr. acid dissolved 0.2767 gms off of steel tag (4.7%), laser mark was unaffected.

- After 12 hrs. acid dissolved 1.8057 gms off of steel tag (30.6%), laser mark was unaffected, now having a distinctly raised feel.

 

 

Sulfuric acid testing:

 

- Acid discolors at approximately 96 hrs., mark appears to be slightly discolored.